[dpdk-dev] [PATCH RFC] dpif-netdev: Add support Intel DPDK based ports.

Prashant Upadhyaya prashant.upadhyaya at aricent.com
Thu Jan 30 11:15:59 CET 2014


Hi Pravin,

Request you to please validate atleast one method to interface VM's with your innovative dpdk port on the OVS.
Preferably IVSHM.
Please do publish the steps for that too.

We really need the above for huge acceptance.

Regards
-Prashant


-----Original Message-----
From: Pravin Shelar [mailto:pshelar at nicira.com]
Sent: Thursday, January 30, 2014 3:00 AM
To: Prashant Upadhyaya
Cc: dev at openvswitch.org; dev at dpdk.org; dpdk-ovs at lists.01.org; Gerald Rogers
Subject: Re: [dpdk-dev] [PATCH RFC] dpif-netdev: Add support Intel DPDK based ports.

On Wed, Jan 29, 2014 at 12:56 AM, Prashant Upadhyaya <prashant.upadhyaya at aricent.com> wrote:
> Hi Pravin,
>
> I think your stuff is on the brink of a creating a mini revolution :)
>
> Some questions inline below --
> +    ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk
> What do you mean by portid here, do you mean the physical interface id like eth0 which I have bound to igb_uio now ?
> If I have multiple interfaces I have assigned igb_uio to, eg. eth0, eth1, eth2 etc., what is the id mapping for those ?
>
Port id is id assigned by DPDK. DPDK interface takes this port id as argument. Currently you need to look at pci id to figure out the device mapping to port id. I know it is clean and I am exploring better interface so that we can specify device names to ovs-vsctl.

> If I have VM's running, then typically how to interface those VM's to this OVS in user space now, do I use the same classical 'tap' interface and add it to the OVS above.

tap device will work, but you would not get performance primarily due to scheduling delay and memcopy.
DPDK has multiple drivers to create interface with KVM guests OS.
those should perform better. I have no tried it yet.

> What is the actual path the data takes from the VM now all the way to the switch, wouldn't it be hypervisor to kernel to OVS switch in user space to other VM/Network ?

Depends on method you use. e.g. Memnic bypass hypervisor and host kernel entirely.

> I think if we can solve the VM to OVS port connectivity remaining in userspace only, then we have a great thing at our hand. Kindly comment on this.
>
right, performance looks pretty good. Still DPDK needs constant polling which consumes more power. RFC ovs-dkdp patch has simple polling which need tweaking for better power usage.

Thanks,
Pravin.



> Regards
> -Prashant
>
>




===============================================================================
Please refer to http://www.aricent.com/legal/email_disclaimer.html
for important disclosures regarding this electronic communication.
===============================================================================


More information about the dev mailing list