[dpdk-dev] [Bug 199] Azure DPDK 18.11 Multiple Processes Example Support
bugzilla at dpdk.org
bugzilla at dpdk.org
Wed Jan 30 01:17:36 CET 2019
https://bugs.dpdk.org/show_bug.cgi?id=199
Bug ID: 199
Summary: Azure DPDK 18.11 Multiple Processes Example Support
Product: DPDK
Version: 18.11
Hardware: x86
OS: Linux
Status: CONFIRMED
Severity: critical
Priority: Normal
Component: examples
Assignee: dev at dpdk.org
Reporter: sju at paloaltonetworks.com
Target Milestone: ---
Hi,
I have a Azure VM with accelerated network enabled with 1 management interface
and 2 data interfaces.
Following the documents from :
https://docs.microsoft.com/en-us/azure/virtual-network/setup-dpdk
I can successfully run testpmd example with 2 data interfaces.
The running command of testpmd is:
./testpmd -w b1f0:00:02.0 -w b4b1:00:02.0 --vdev="net_vdev_netvsc0,iface=eth1"
--vdev="net_vdev_netvsc1,iface=eth2"
However, if I try the multiple process version based on
https://doc.dpdk.org/guides/sample_app_ug/multi_process.html, it failed. The
running command is:
./symmetric_mp -w b1f0:00:02.0 -w b4b1:00:02.0
--vdev="net_vdev_netvsc0,iface=eth1" --vdev="net_vdev_netvsc1,iface=eth2" -l 1
-n 4 --proc-type=auto -- -p 3 --num-procs=4 --proc-id=0
EAL: Detected 20 lcore(s)
EAL: Detected 2 NUMA nodes
EAL: Auto-detected process type: PRIMARY
EAL: Multi-process socket /var/run/dpdk/rte/mp_socket
EAL: No free hugepages reported in hugepages-1048576kB
EAL: Probing VFIO support...
EAL: WARNING: cpu flags constant_tsc=yes nonstop_tsc=no -> using unreliable
clock cycles !
EAL: PCI device b1f0:00:02.0 on NUMA socket -1
EAL: Invalid NUMA socket, default to 0
EAL: probe driver: 15b3:1004 net_mlx4
PMD: net_mlx4: PCI information matches, using device "mlx4_1" (VF: true)
PMD: net_mlx4: 1 port(s) detected
PMD: net_mlx4: port 1 MAC address is 00:0d:3a:f9:47:24
EAL: PCI device b4b1:00:02.0 on NUMA socket -1
EAL: Invalid NUMA socket, default to 0
EAL: probe driver: 15b3:1004 net_mlx4
PMD: net_mlx4: PCI information matches, using device "mlx4_2" (VF: true)
PMD: net_mlx4: 1 port(s) detected
PMD: net_mlx4: port 1 MAC address is 00:0d:3a:f9:48:8b
net_vdev_netvsc: probably using routed NetVSC interface "eth1" (index 3)
rte_pmd_tap_probe(): Initializing pmd_tap for net_tap_vsc0 as dtap0
net_vdev_netvsc: probably using routed NetVSC interface "eth2" (index 4)
rte_pmd_tap_probe(): Initializing pmd_tap for net_tap_vsc1 as dtap1
Checking link statusdone
APP: Finished Process Init.
Lcore 1 has nothing to do
It shows it has nothing to do and quits. I am not sure how to run Azure DPDK
with symmetric_mp.
Could you help me?
Thanks.
Suyang
--
You are receiving this mail because:
You are the assignee for the bug.
More information about the dev
mailing list