<html>
    <head>
      <base href="https://bugs.dpdk.org/">
    </head>
    <body><table border="1" cellspacing="0" cellpadding="8" class="bz_new_table">
        <tr>
          <th>Bug ID</th>
          <td><a class="bz_bug_link 
          bz_status_UNCONFIRMED "
   title="UNCONFIRMED - RTE flow: Port state changing to error when RTE flow is enabled/disabled on Intel X722"
   href="https://bugs.dpdk.org/show_bug.cgi?id=1217">1217</a>
          </td>
        </tr>

        <tr>
          <th>Summary</th>
          <td>RTE flow: Port state changing to error when RTE flow is enabled/disabled on Intel X722
          </td>
        </tr>

        <tr>
          <th>Product</th>
          <td>DPDK
          </td>
        </tr>

        <tr>
          <th>Version</th>
          <td>22.03
          </td>
        </tr>

        <tr>
          <th>Hardware</th>
          <td>x86
          </td>
        </tr>

        <tr>
          <th>OS</th>
          <td>Linux
          </td>
        </tr>

        <tr>
          <th>Status</th>
          <td>UNCONFIRMED
          </td>
        </tr>

        <tr>
          <th>Severity</th>
          <td>major
          </td>
        </tr>

        <tr>
          <th>Priority</th>
          <td>Normal
          </td>
        </tr>

        <tr>
          <th>Component</th>
          <td>other
          </td>
        </tr>

        <tr>
          <th>Assignee</th>
          <td>dev@dpdk.org
          </td>
        </tr>

        <tr>
          <th>Reporter</th>
          <td>lthammin@usc.edu
          </td>
        </tr>

        <tr>
          <th>Target Milestone</th>
          <td>---
          </td>
        </tr></table>
      <p>
        <div class="bz_comment_block">
          <pre class="bz_comment_text">Created <span class=""><a href="attachment.cgi?id=249" name="attach_249" title="rte_flow_port_state_error_on_X722 logs">attachment 249</a> <a href="attachment.cgi?id=249&action=edit" title="rte_flow_port_state_error_on_X722 logs">[details]</a></span>
rte_flow_port_state_error_on_X722 logs

When RTE flows are enabled and disabled couple of times on Intel X722
interface, the port state turns from Up/down to error state with error logs
"Interface TenGigabitEthernetb5/0/0 error -95: Unknown error -95",
"i40e_dev_sync_phy_type(): Failed to sync phy type: status=-7".

Please check the attachment for logs.
          </pre>
        </div>
      </p>


      <hr>
      <span>You are receiving this mail because:</span>

      <ul>
          <li>You are the assignee for the bug.</li>
      </ul>
      <div itemscope itemtype="http://schema.org/EmailMessage">
        <div itemprop="action" itemscope itemtype="http://schema.org/ViewAction">
          
          <link itemprop="url" href="https://bugs.dpdk.org/show_bug.cgi?id=1217">
          <meta itemprop="name" content="View bug">
        </div>
        <meta itemprop="description" content="Bugzilla bug update notification">
      </div>
    </body>