Unable to perform metering on Mellanox VF

Asaf Penso asafp at nvidia.com
Tue Mar 22 14:12:18 CET 2022


Hello
In a different threads you mentioned that RSS doesn't work, but here even the meter doesn't work.
What's the difference?

In you work with VF you need to define it as trusted.
Check mlx5.rst for details.

Regards,
Asaf Penso
________________________________
From: Ariba Ehtesham <ariba at dreambigsemi.com>
Sent: Thursday, March 17, 2022 12:28:06 PM
To: users at dpdk.org <users at dpdk.org>
Subject: Re: Unable to perform metering on Mellanox VF

Followup required

Regards,
Ariba Ehtesham
________________________________
From: Ariba Ehtesham
Sent: Friday, March 11, 2022 10:30 AM
To: users at dpdk.org <users at dpdk.org>
Subject: Unable to perform metering on Mellanox VF

Hi ,
Can anyone please guide me why I am unable to run metering with Mellanox VF . (connect x6-Dx)

$ sudo ./build/app/dpdk-testpmd -l 1,2,3,4,5,7,9,11,13,15,17  -n 4 -a 04:01.2 --file-prefix=vf1 -- -i --rxq=8 --txq=8 --port-topology=chained --nb-cores=8 --rxd=4096 --txd=4096 --disable-rss

testpmd> add port meter profile srtcm_rfc2697 0 0 1000 1000 0 0
cause unspecified: Meter is not supported (error 1)

Regards,
Ariba Ehtesham
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://mails.dpdk.org/archives/users/attachments/20220322/85eb910c/attachment.htm>


More information about the users mailing list