Thanks Konstantin for your reply.

Konstantin, 

Would you be able in providing more details as to ixgbe VF mirroring? 
Would you have any valuable URL's or documentation that explain this in detail and/or provide examples?

Thanks in advance.

Best Regards,
Sami.

-----Original Message-----
From: Ananyev, Konstantin [mailto:konstantin.ananyev at intel.com] 
Sent: Friday, May 15, 2015 5:31 AM
To: Richardson, Bruce; Stephen Hemminger
Cc: dev at dpdk.org; Assaad, Sami (Sami)
Subject: RE: [dpdk-dev] How do you setup a VM in Promiscuous Mode using PCI Pass-Through (SR-IOV)?



> -----Original Message-----
> From: dev [mailto:dev-bounces at dpdk.org] On Behalf Of Bruce Richardson
> Sent: Friday, May 15, 2015 10:27 AM
> To: Stephen Hemminger
> Cc: dev at dpdk.org; Assaad, Sami (Sami)
> Subject: Re: [dpdk-dev] How do you setup a VM in Promiscuous Mode using PCI Pass-Through (SR-IOV)?
> 
> On Thu, May 14, 2015 at 04:47:19PM -0700, Stephen Hemminger wrote:
> > On Thu, 14 May 2015 21:38:24 +0000
> > "Assaad, Sami (Sami)" <sami.assaad at alcatel-lucent.com> wrote:
> >
> > > Hello,
> > >
> > > My Hardware consists of the following:
> > >   - DL380 Gen 9 Server supporting two Haswell Processors (Xeon CPU E5-2680 v3 @ 2.50GHz)
> > >   - An x540 Ethernet Controller Card supporting 2x10G ports.
> > >
> > > Software:
> > >   - CentOS 7 (3.10.0-229.1.2.el7.x86_64)
> > >   - DPDK 1.8
> > >
> > > I want all the network traffic received on the two 10G ports to be 
> > > transmitted to my VM. The issue is that the Virtual Function /
> Physical Functions have setup the internal virtual switch to only 
> route Ethernet packets with destination MAC address matching the VM 
> virtual interface MAC. How can I configure my virtual environment to provide all network traffic to the VM...i.e. set the virtual functions for both PCI devices in Promiscuous mode?
> > >
> > > [ If a l2fwd-vf example exists, this would actually solve this 
> > > problem ... Is there a DPDK l2fwd-vf example available? ]
> > >
> > >
> > > Thanks in advance.
> > >
> > > Best Regards,
> > > Sami Assaad.
> >
> > This is a host side (not DPDK) issue.
> >
> > Intel PF driver will not allow guest (VF) to go into promiscious 
> > mode since it would allow traffic stealing which is a security violation.
> 
> Could you maybe try passing the PF directly into the VM, rather than a 
> VF based off it? Since you seem to want all traffic to go to the one 
> VM, there seems little point in creating a VF on the device, and 
> should let the VM control the whole NIC directly.

As I remember, with ixgbe it is possible to make one VF a mirror (receive a copy of all traffic).
Konstantin

> 