[dpdk-dev] [PATCH v1 5/6] doc: update sample app with unknown speed

Andrew Rybchenko arybchenko at solarflare.com
Sun May 3 15:57:03 CEST 2020


On 5/2/20 10:35 PM, Ivan Dyukov wrote:
> 01.05.2020 16:28, Andrew Rybchenko пишет:
>> On 4/27/20 12:57 PM, Ivan Dyukov wrote:
>>> Signed-off-by: Ivan Dyukov <i.dyukov at samsung.com>
>>> ---
>>>   doc/guides/sample_app_ug/link_status_intr.rst | 3 ++-
>>>   1 file changed, 2 insertions(+), 1 deletion(-)
>>>
>>> diff --git a/doc/guides/sample_app_ug/link_status_intr.rst 
>>> b/doc/guides/sample_app_ug/link_status_intr.rst
>>> index 5283be8b7..6ebc707b7 100644
>>> --- a/doc/guides/sample_app_ug/link_status_intr.rst
>>> +++ b/doc/guides/sample_app_ug/link_status_intr.rst
>>> @@ -177,7 +177,8 @@ An example callback function that has been 
>>> written as indicated below.
>>>               printf("Failed to get port %d link status: %s\n\n",
>>>                      port_id, rte_strerror(-ret));
>>>           } else if (link.link_status) {
>>> -            printf("Port %d Link Up - speed %u Mbps - %s\n\n", 
>>> port_id, (unsigned)link.link_speed,
>>> +            printf("Port %d Link Up - speed %u%s - %s\n\n", port_id, 
>>> (unsigned)link.link_speed,
>>> +                  (link.link_speed == UINT32_MAX) ? ("(UNKNOWN)") : 
>>> (" Mbps"),
>>>                     (link.link_duplex == ETH_LINK_FULL_DUPLEX) ? 
>>> ("full-duplex") : ("half-duplex"));
>>>           } else
>>>               printf("Port %d Link Down\n\n", port_id);
>>>
>> I think that 0 looks nicer than UINT32_MAX when printed as integer
>> keeping in mind that it is unknown.
>>
> zero will mislead developers about real value of the link_speed. 
> therefore we should print real value of the speed or print nothing. e.g.
>
>     if (link.link_speed == UINT32_MAX)
>
>          printf("Port %d Link Up - speed UNKNOWN - %s\n\n", port_id,
>                     (link.link_duplex == ETH_LINK_FULL_DUPLEX) ? 
> ("full-duplex") : ("half-duplex"));
>     else
>
>          printf("Port %d Link Up - speed %u Mbps - %s\n\n", port_id, 
> link.link_speed,
>
>                      (link.link_duplex == ETH_LINK_FULL_DUPLEX) ? 
> ("full-duplex") : ("half-duplex"));

I'm not sure about 0 to be misleading, but it could be.
Above definitely will look better in stdout.
The only problem is code duplication in many-many places.
May be add simple function in ethdev to do it and use it in
all examples?

Please, wait more feedback before doing it.