[dpdk-dev] DPDK Packet drop/Out of sequence issue with Jumbo frames on MLX ConnectX-4 Lx NIC

Balbeer Tiwari Balbeer.Tiwari at radisys.com
Tue Jul 20 17:17:50 CEST 2021


Hi Asaf,



Please see details, let me know if more details required.

What DPDK version do you use?

DPDK-20.05

What EAL and devargs value are being used?

Following are the argv at eal_init

1005              if (rte_eal_init(argc, argv) < 0)

(gdb) p argv

$7 = {0x72bce60 "fast_pkt_app", 0x72bce90 "-c 6c", 0x72bcec0 "-m 1024", 0x72bcef0 "-n 1", 0x72bcf20 "--file-prefix=gnb_du_rte_config", 0x72bcf50 "--proc-type=auto", 0x72bcf80 "-w0000:c1:00.0",

  0x72bcfb0 "-w0000:c1:00.1", 0x72bcfe0 "", 0x72bd010 ""}

(gdb)



Regards,

Balbeer



-----Original Message-----
From: Asaf Penso <asafp at nvidia.com>
Sent: Tuesday, July 20, 2021 8:03 PM
To: Balbeer Tiwari <Balbeer.Tiwari at radisys.com>; dev at dpdk.org
Subject: RE: [dpdk-dev] DPDK Packet drop/Out of sequence issue with Jumbo frames on MLX ConnectX-4 Lx NIC



The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.



Hello Balbeer,



Can you please provide more details?

What DPDK version do you use?

What EAL and devargs value are being used?



Regards,

Asaf Penso



>-----Original Message-----

>From: dev <dev-bounces at dpdk.org<mailto:dev-bounces at dpdk.org>> On Behalf Of Balbeer Tiwari

>Sent: Tuesday, July 20, 2021 4:54 PM

>To: dev at dpdk.org<mailto:dev at dpdk.org>

>Subject: [dpdk-dev] DPDK Packet drop/Out of sequence issue with Jumbo

>frames on MLX ConnectX-4 Lx NIC

>

>Hi There,

>

>I am using MLX ConnectX-4 Lx with DPDK and with this I am observing

>packet drops at receiver if size greater than ~8k(jumbo) frames.

>Smaller packets go through fine. Its being run directly on baremetal

>with Centos 8.3.  Please can you share if there is any fix for this.

>

>Regards,

>Balbeer


More information about the dev mailing list