[dpdk-dev] [PATCH v7 2/5] vhost: implement rte_power_monitor API
David Hunt
david.hunt at intel.com
Fri Oct 22 14:34:24 CEST 2021
On 19/10/2021 5:38 AM, Xia, Chenbo wrote:
>> -----Original Message-----
>> From: Li, Miao <miao.li at intel.com>
>> Sent: Monday, October 18, 2021 10:17 PM
>> To: dev at dpdk.org
>> Cc: Xia, Chenbo <chenbo.xia at intel.com>; maxime.coquelin at redhat.com; Li, Miao
>> <miao.li at intel.com>
>> Subject: [PATCH v7 2/5] vhost: implement rte_power_monitor API
>>
>> This patch defines rte_vhost_power_monitor_cond which is used to pass
>> some information to vhost driver. The information is including the address
>> to monitor, the expected value, the mask to extract value read from 'addr',
>> the value size of monitor address, the match flag used to distinguish the
>> value used to match something or not match something. Vhost driver can use
>> these information to fill rte_power_monitor_cond.
>>
>> Signed-off-by: Miao Li <miao.li at intel.com>
>> ---
>> doc/guides/rel_notes/release_21_11.rst | 4 +++
>> lib/vhost/rte_vhost.h | 42 ++++++++++++++++++++++++++
>> lib/vhost/version.map | 3 ++
>> lib/vhost/vhost.c | 38 +++++++++++++++++++++++
>> 4 files changed, 87 insertions(+)
>>
>> diff --git a/doc/guides/rel_notes/release_21_11.rst
>> b/doc/guides/rel_notes/release_21_11.rst
>> index c298844898..a497674352 100644
>> --- a/doc/guides/rel_notes/release_21_11.rst
>> +++ b/doc/guides/rel_notes/release_21_11.rst
>> @@ -80,6 +80,10 @@ New Features
>> Added macros ETH_RSS_IPV4_CHKSUM and ETH_RSS_L4_CHKSUM, now IPv4 and
>> TCP/UDP/SCTP header checksum field can be used as input set for RSS.
>>
>> +* **Added power monitor API in vhost library.**
>> +
>> + Added an API to support power monitor in vhost library.
>> +
>> * **Updated virtio PMD.**
>>
>> Implement rte_power_monitor API in virtio PMD.
>> diff --git a/lib/vhost/rte_vhost.h b/lib/vhost/rte_vhost.h
>> index fd372d5259..6f0915b98f 100644
>> --- a/lib/vhost/rte_vhost.h
>> +++ b/lib/vhost/rte_vhost.h
>> @@ -292,6 +292,31 @@ struct vhost_device_ops {
>> void *reserved[1]; /**< Reserved for future extension */
>> };
>>
>> +/**
>> + * Power monitor condition.
>> + */
>> +struct rte_vhost_power_monitor_cond {
>> + /**< Address to monitor for changes */
>> + volatile void *addr;
>> + /**< If the `mask` is non-zero, location pointed
>> + * to by `addr` will be read and masked, then
>> + * compared with this value.
>> + */
>> + uint64_t val;
>> + /**< 64-bit mask to extract value read from `addr` */
>> + uint64_t mask;
>> + /**< Data size (in bytes) that will be read from the
>> + * monitored memory location (`addr`).
>> + */
>> + uint8_t size;
>> + /**< If 1, and masked value that read from 'addr' equals
>> + * 'val', the driver should skip core sleep. If 0, and
>> + * masked value that read from 'addr' does not equal 'val',
>> + * the driver should skip core sleep.
>> + */
>> + uint8_t match;
>> +};
>> +
>> /**
>> * Convert guest physical address to host virtual address
>> *
>> @@ -903,6 +928,23 @@ int rte_vhost_vring_call(int vid, uint16_t vring_idx);
>> */
>> uint32_t rte_vhost_rx_queue_count(int vid, uint16_t qid);
>>
>> +/**
>> + * Get power monitor address of the vhost device
>> + *
>> + * @param vid
>> + * vhost device ID
>> + * @param queue_id
>> + * vhost queue ID
>> + * @param pmc
>> + * power monitor condition
>> + * @return
>> + * 0 on success, -1 on failure
>> + */
>> +__rte_experimental
>> +int
>> +rte_vhost_get_monitor_addr(int vid, uint16_t queue_id,
>> + struct rte_vhost_power_monitor_cond *pmc);
>> +
>> /**
>> * Get log base and log size of the vhost device
>> *
>> diff --git a/lib/vhost/version.map b/lib/vhost/version.map
>> index 8ebde3f694..c8599ddb97 100644
>> --- a/lib/vhost/version.map
>> +++ b/lib/vhost/version.map
>> @@ -85,4 +85,7 @@ EXPERIMENTAL {
>> rte_vhost_async_channel_register_thread_unsafe;
>> rte_vhost_async_channel_unregister_thread_unsafe;
>> rte_vhost_clear_queue_thread_unsafe;
>> +
>> + # added in 21.11
>> + rte_vhost_get_monitor_addr;
>> };
>> diff --git a/lib/vhost/vhost.c b/lib/vhost/vhost.c
>> index 9540522dac..36c896c9e2 100644
>> --- a/lib/vhost/vhost.c
>> +++ b/lib/vhost/vhost.c
>> @@ -1889,5 +1889,43 @@ rte_vhost_async_get_inflight(int vid, uint16_t queue_id)
>> return ret;
>> }
>>
>> +int
>> +rte_vhost_get_monitor_addr(int vid, uint16_t queue_id,
>> + struct rte_vhost_power_monitor_cond *pmc)
>> +{
>> + struct virtio_net *dev = get_device(vid);
>> + struct vhost_virtqueue *vq;
>> +
>> + if (dev == NULL)
>> + return -1;
>> + if (queue_id >= VHOST_MAX_VRING)
>> + return -1;
>> +
>> + vq = dev->virtqueue[queue_id];
>> + if (vq == NULL)
>> + return -1;
>> +
>> + if (vq_is_packed(dev)) {
>> + struct vring_packed_desc *desc;
>> + desc = vq->desc_packed;
>> + pmc->addr = &desc[vq->last_avail_idx].flags;
>> + if (vq->avail_wrap_counter)
>> + pmc->val = VRING_DESC_F_AVAIL;
>> + else
>> + pmc->val = VRING_DESC_F_USED;
>> + pmc->mask = VRING_DESC_F_AVAIL | VRING_DESC_F_USED;
>> + pmc->size = sizeof(desc[vq->last_avail_idx].flags);
>> + pmc->match = 1;
>> + } else {
>> + pmc->addr = &vq->avail->idx;
>> + pmc->val = vq->last_avail_idx & (vq->size - 1);
>> + pmc->mask = vq->size - 1;
>> + pmc->size = sizeof(vq->avail->idx);
>> + pmc->match = 0;
>> + }
>> +
>> + return 0;
>> +}
>> +
>> RTE_LOG_REGISTER_SUFFIX(vhost_config_log_level, config, INFO);
>> RTE_LOG_REGISTER_SUFFIX(vhost_data_log_level, data, WARNING);
>> --
>> 2.25.1
> Reviewed-by: Chenbo Xia <chenbo.xia at intel.com>
Acked-by: David Hunt <david.hunt at intel.com>
More information about the dev
mailing list