[PATCH v1 1/2] app/testpmd: mask VLAN TCI when specified
Anatoly Burakov
anatoly.burakov at intel.com
Tue Jun 16 12:27:38 CEST 2026
Currently, when testpmd command `...vlan tci is 0x1234`, the VLAN TCI field
is being specified in spec, but is not masked in mask. Add full mask to
VLAN TCI when specified.
Signed-off-by: Anatoly Burakov <anatoly.burakov at intel.com>
---
app/test-pmd/cmdline_flow.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/app/test-pmd/cmdline_flow.c b/app/test-pmd/cmdline_flow.c
index 67f200f2e3..0b7d268535 100644
--- a/app/test-pmd/cmdline_flow.c
+++ b/app/test-pmd/cmdline_flow.c
@@ -4610,7 +4610,8 @@ static const struct token token_list[] = {
.help = "tag control information",
.next = NEXT(item_vlan, NEXT_ENTRY(COMMON_UNSIGNED),
item_param),
- .args = ARGS(ARGS_ENTRY_HTON(struct rte_flow_item_vlan, hdr.vlan_tci)),
+ .args = ARGS(ARGS_ENTRY_MASK_HTON(struct rte_flow_item_vlan,
+ hdr.vlan_tci, "\xff\xff")),
},
[ITEM_VLAN_PCP] = {
.name = "pcp",
--
2.47.3