[dpdk-users] flow_filtering failed on mlx5

Ori Kam orika at mellanox.com
Mon Nov 5 14:54:42 CET 2018


Glad to help,

That’s depends on the NIC but normally it should just be ETH / IPV4 traffic.

Best,
Ori

From: Cliff Burdick <shaklee3 at gmail.com>
Sent: Monday, November 5, 2018 3:42 PM
To: Ori Kam <orika at mellanox.com>
Cc: Shahaf Shuler <shahafs at mellanox.com>; users <users at dpdk.org>
Subject: Re: [dpdk-users] flow_filtering failed on mlx5

Thanks Ori! I'll test out the patch today. Just to make sure, by removing the vlan item, does that not allow vlan tags anymore, or is it just ignoring one if present?

On Mon, Nov 5, 2018, 05:18 Ori Kam <orika at mellanox.com<mailto:orika at mellanox.com> wrote:
Hi Cliff,

There was an issue I solved it, and submitted relevant patches.
You can look at them:

http://patches.dpdk.org/patch/47806/<https://emea01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fpatches.dpdk.org%2Fpatch%2F47806%2F&data=02%7C01%7Corika%40mellanox.com%7Cbef44376afe4405d952508d64324743c%7Ca652971c7d2e4d9ba6a4d149256f461b%7C0%7C0%7C636770221184223602&sdata=gab9ZvUlVgF81iuwsiK22DGFwLx0kutf%2BJrLe54ciFw%3D&reserved=0>
http://patches.dpdk.org/patch/47807/<https://emea01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fpatches.dpdk.org%2Fpatch%2F47807%2F&data=02%7C01%7Corika%40mellanox.com%7Cbef44376afe4405d952508d64324743c%7Ca652971c7d2e4d9ba6a4d149256f461b%7C0%7C0%7C636770221184233602&sdata=ZJJM7bIF5Ot1La8uea6gMlf64BKYn5EZIWHNnYZlR3E%3D&reserved=0>

Best,
Ori

> -----Original Message-----
> From: Shahaf Shuler
> Sent: Monday, November 5, 2018 9:10 AM
> To: Cliff Burdick <shaklee3 at gmail.com<mailto:shaklee3 at gmail.com>>; users <users at dpdk.org<mailto:users at dpdk.org>>; Ori Kam
> <orika at mellanox.com<mailto:orika at mellanox.com>>
> Subject: RE: [dpdk-users] flow_filtering failed on mlx5
>
> +Ori the maintainer of the example code.
>
> Saturday, November 3, 2018 5:31 AM, Cliff Burdick:
> > Subject: [dpdk-users] flow_filtering failed on mlx5
> >
> > Hi I'm trying to run the flow_filtering example on a connectx-5, and it seems
> > to fail with dpdk 18.08:
> >
> > $ sudo ./build/flow -l 1 -n 1
> > EAL: Detected 48 lcore(s)
> > EAL: Detected 2 NUMA nodes
> > EAL: Multi-process socket /var/run/dpdk/rte/mp_socket
> > EAL: Probing VFIO support...
> > EAL: PCI device 0000:01:00.0 on NUMA socket 0
> > EAL:   probe driver: 15b3:1013 net_mlx5
> > EAL: PCI device 0000:01:00.1 on NUMA socket 0
> > EAL:   probe driver: 15b3:1013 net_mlx5
> > EAL: PCI device 0000:81:00.0 on NUMA socket 1
> > EAL:   probe driver: 8086:1528 net_ixgbe
> > EAL: PCI device 0000:81:00.1 on NUMA socket 1
> > EAL:   probe driver: 8086:1528 net_ixgbe
> > EAL: PCI device 0000:82:00.0 on NUMA socket 1
> > EAL:   probe driver: 15b3:1013 net_mlx5
> > EAL: PCI device 0000:82:00.1 on NUMA socket 1
> > EAL:   probe driver: 15b3:1013 net_mlx5
> > :: warn: 5 ports detected, but we use only one: port 0
> > :: initializing port: 0
> > Ethdev port_id=0 requested Tx offloads 0x3f doesn't match Tx offloads
> > capabilities 0xc86af in rte_eth_dev_configure()
> > EAL: Error - exiting with code: 1
> >   Cause: :: cannot configure device: err=-22, port=0
> >
> >
> > Has anyone got this to work?


More information about the users mailing list